Search Results

Search results for "AIF-SS"

Water Hammer Arrestor 304 Stainless Flanged DN80 to DN300

Anti water hammer valve stainless steel AIF\nFlange: DN80, DN100, DN125, DN150, DN200, DN250 or DN300 PN16 flange, option JIS10K or ANSI150Lb\nBody: 304 stainless steel\nAir chamber: 2000cc to 67860cc according to port size\nChamber pressure: 2.5 Bar, can be adjusted via Schrader valve, displayed by pressure gauge (Included)\nPressure: 0 to 12 Bar, tested 32 Bar\nMedia: water\nSeals: NBR\nTemperature: -5°C to +80°C\nMounting: any position\n\nThe AIF anti water hammer valve (water shock absorber) works on a pressure air chamber behind a flexible diaphragm principle and does not suffer from response lag time, friction wear, sealing leakage or air bubble loss that can be seen in other designs. \n\nGenerally water hammer occurs downstream from check or non-return valves on when the length of a horizontal pipe exceed 50 meters or when pumps are used in pipeline systems during start or shut down. Installing the AIF series in line water hammer arrestor will significantly reduce the water hammer, banging effects of water pressure waves caused by sudden changes in water movement. \nProtected by patent Number 140580

0 in stock Model: AIF-304

Water Hammer Arrestor 316 Stainless Flanged DN80 to DN300 AIF-316

Anti water hammer valve stainless steel AIF\nFlange: DN80, DN100, DN125, DN150, DN200, DN250 or DN300 PN16 flange, option JIS10K or ANSI150Lb\nBody: 316 stainless steel\nAir chamber: 2000cc to 67860cc according to port size\nChamber pressure: 2.5 Bar, can be adjusted via Schrader valve, displayed by pressure gauge (Included)\nPressure: 0 to 12 Bar, tested 32 Bar\nMedia: water\nSeals: NBR\nTemperature: -5°C to +80°C\nMounting: any position\n\nThe AIF anti water hammer valve (water shock absorber) works on a pressure air chamber behind a flexible diaphragm and does not suffer from response lag time, friction wear, sealing leakage or air bubble loss that can be seen in other designs. \n\nGenerally water hammer occurs downstream from check or non-return valves on when the length of a horizontal pipe exceed 50 meters or when pumps are used in pipeline systems during start or shut down. Installing the AIF series in line water hammer arrestor will significantly reduce the water hammer, banging effects of water pressure waves caused by sudden changes in water movement. \nProtected by patent Number 140580

0 in stock Model: AIF-316

Water Hammer Arrestor ductile iron flange DN80 upto DN300 AIF-D

Anti water hammer valve Ductile Iron AIF\nFlange: DN80, DN100, DN125, DN150, DN200, DN250 or DN300 PN16 flange, option JIS10K or ANSI150Lb\nBody: Ductile Iron\nAir chamber: 2000cc to 67860cc according to port size\nChamber pressure: 2.5 Bar, can be adjusted via Schrader valve, displayed by pressure gauge (Included)\nPressure: 0 to 12 Bar, tested 32 Bar\nMedia: water\nSeals: NBR\nTemperature: -5°C to +80°C\nMounting: any position\n\nThe AIF-D anti water hammer valve (water shock absorber) works on a pressurised air chamber and a flexible diaphragm principle and does not suffer from response lag time, friction wear, sealing leakage or air bubble loss that can be seen in other designs. \n\nGenerally water hammer occurs downstream from check or non-return valves on when the length of a horizontal pipe exceed 50 meters or when pumps are used in pipeline systems during start or shut down. Installing the AIF series in line water hammer arrestor will significantly reduce the water hammer, banging effects of water pressure waves caused by sudden changes in water movement. \nProtected by patent Number 140580

0 in stock Model: AIF-D

Water Hammer Arrestor ductile iron epoxy flange DN80-DN300 AIF-DE

Anti water hammer valve Ductile Iron Epoxy Coated AIF\nFlange: DN80, DN100, DN125, DN150, DN200, DN250 or DN300 PN16 flange, option JIS10K or ANSI150Lb\nBody: Ductile Iron epoxy coated\nAir chamber: 2000cc to 67860cc according to port size\nChamber pressure: 2.5 Bar, can be adjusted via Schrader valve, displayed by pressure gauge (Included)\nPressure: 0 to 12 Bar, tested 32 Bar\nMedia: water\nSeals: NBR\nTemperature: -5°C to +80°C\nMounting: any position\n\nThe AIF-D anti water hammer valve (water shock absorber) works on a pressure air chamber behind a flexible diaphragm principle and does not suffer from response lag time, friction wear, sealing leakage or air bubble loss that can be seen in other designs. \n\nGenerally water hammer occurs downstream from check or non-return valves on when the length of a horizontal pipe exceed 50 meters or when pumps are used in pipeline systems during start or shut down. Installing the AIF series in line water hammer arrestor will significantly reduce the water hammer, banging effects of water pressure waves caused by sudden changes in water movement. \nProtected by patent Number 140580

0 in stock Model: AIF-DE

Water Hammer Arrestor Bronze Flanged DN80 to DN300 AIF-B

Flanged Anti water hammer valve Bronze AIF\nFlange: DN80, DN100, DN125, DN150, DN200, DN250 or DN300 PN16 flange, option JIS10K or ANSI150Lb\nBody: Bronze\nAir chamber: 2000cc to 67860cc according to port size\nChamber pressure: 2.5 Bar, can be adjusted via Schrader valve, displayed by pressure gauge (Included)\nPressure: 0 to 12 Bar, tested 32 Bar\nMedia: water\nSeals: NBR\nTemperature: -5°C to +80°C\nMounting: any position\n\nThe AIF anti water hammer valve (water shock absorber) works on a pressure air chamber behind a flexible diaphragm principle and does not suffer from response lag time, friction wear, sealing leakage or air bubble loss that can be seen in other designs. \n\nGenerally water hammer occurs downstream from check or non-return valves on when the length of a horizontal pipe exceed 50 meters or when pumps are used in pipeline systems during start or shut down. Installing the AIF series in line water hammer arrestor will significantly reduce the water hammer, banging effects of water pressure waves caused by sudden changes in water movement. \nProtected by patent Number 140580

0 in stock Model: AIF-B